36 cells in series
3 cells parallel
Peak Voltage 100% SOC 151.2 volts
95% SOC voltage 149.4 volts
80% SOC voltage 144 volts
Nominal Voltage (10% SOC perfectly balanced) 133.2 volts
Amp hour capacity 13.2Ah
Watt Hour Capacity 1758 Wh (nominal voltage * Ah capacity)
Internal Power Wire Gauge: 8 AWG Silicone x 3P (75C 150v) or 8AWG x 6P (125C 150v).
Balance Cable Wire Gauge: 22 AWG silicone (maximum recommended balance current is 2.2 amps)(max charging voltage is 4.2 volts per cell)
C-rating: 75C
Continuous max discharge 120-165 amps (depends on environmental temperature. 165 amps if ambient temperature is 86 F)(conservative 10C numbers)
10 second max discharge 1000 amps (please read Sleeper Cell manual for explanation of discharge numbers)(hot discharge limit is for internal temp of 110 F.
2 second max discharge 1200 amps
<1 second max discharge 1320 amps
Nominal charge rate 7.5 amps (see operations manual for explanation)
Max charge rate 30 amps
Case Material: Polycarbonate
Pictures
1st Image is 150v 13.2Ah 75C battery pack (Post-Internal Fuse Mod((standard construction packs)
2nd Image is 150v 13.2Ah 75C (DB37 connector)
3rd image is 100v 20Ah 125C variant inside Halfscale made custom steel case for mounting to back of dragster. ($3200.00)(not standard yet)
4th image is 150v 13.2 Ah 75C pack with permanent Orion BMS2 balance cable.
5th image is Radlock case prototype.
Please contact Nathan for addon information or connector type.
Anderson SB175 Power Connector (shown in picture) or finger safe Radlock/Surlok Connectors
Includes internal fuse for short circuit or over-discharge. Fuse curve on Junior Dragster page or support section of Sleeper Cell page.
BMS output cable is either straight Orion BMS cell tap harness or DB37.
6 thermistor cables standard on 100v and 8 on 150v. 80 thermistors max is available with purchase of Orion Thermistor Expansion module.